Add to Cart
Growatt's 3600MTL / 4200MTL / 5000MTL Summary
Leading-Edge Technology
> Maximum efficiency of 97.9 % and wide input voltage range
> Muti MPP controller
> Internal DC switch
> Transformerless H6 topology
> Compact design
> Muti MPP control
> MTL-String
> Bluetooth technology
> Easy installation
> Sound control
Europe /Australia ENS
> Simple national setting of line supply monitoring(ENS)
> Easy country configuration
> Muti-language display
> Currently available for Germany, France, UK, Austria, Switzerland, Italy and Spain
Model Specifications |
Growatt 3600MTL-US |
Growatt 4200MTL-US |
Growatt 5000MTL-US |
Input data |
|
||
Max. DC power |
3800W |
4400W |
5200W |
Max. DC voltage |
600V |
600V |
600V |
PV voltage range MPPT |
120V-550V |
120V-550V |
120V-550V |
Max. number of parallel strings |
2 |
2 |
2 |
Number of MPP trackers |
2(can parrallel) |
2(can parrallel) |
2(can parrallel) |
Max.DC power on each MPP tracker |
2000W |
2500W |
3000W |
Max. input current of the MPP tracker |
10A/10A |
15A/15A |
15A/15A |
Output data |
|
||
Nominal AC ouput power |
3600W |
4200W |
4600W |
Nominal AC voltage |
Default:240Vac Split phase optional:208, 240 or 277single phase |
||
AC voltage range |
183~228V@208Vac 211~264V@240Vac 244~305V@277Vac |
||
Nominal AC grid frequency |
60Hz |
||
AC grid frequency range |
59.3--60.5Hz |
||
Nominal output current |
17.4A / 15A /13A |
20.2A / 17.5A / 15A |
22A / 19A / 16.7A |
Max. output current |
18A / 17.1A /14.8A |
21A / 20A / 17.2A |
23A / 21.8A / 18.8A |
Phase shift (cos φ) at nominal |
1 |
1 |
1 |
THDI at nominal |
<3% |
<3% |
<3% |
Phase conductors/connection phase |
1/2 |
1/2 |
1/2 |
Efficiency |
|
||
Max.efficiency |
97.6% |
97.9% |
97.9% |
CEC.efficiency |
97% |
97.4% |
97.4% |
MPPT efficiency |
99.5% |
99.5% |
99.5% |
Protection devices |
|
||
DC reverse polarity protection |
yes |
yes |
yes |
PV Ground fault protection |
yes |
yes |
yes |
Input backfeed current |
Negligible |
Negligible |
Negligible |
Insulation Resistance low protection |
yes |
yes |
yes |
AC short-circuitprotection |
yes |
yes |
yes |
Grid monitoring |
yes |
yes |
yes |
Anti islanding protection |
yes |
yes |
yes |
General Data |
|
||
Dimensions (W / D / H)in mm |
360/510/188 |
360/510/188 |
360/510/188 |
Weight |
24KG |
24KG |
24KG |
Altitude |
Up to 2000m without power derating |
||
Operating temperature range |
–25 °C ... +60 °C |
–25 °C ... +60 °C |
–25 °C ... +60 °C |
Continuous full output power temperature range |
-25 °C ... +45 °C |
-25 °C ... +45 °C |
-25 °C ... +45 °C |
Noise emission (typical) |
≤ 25 dB(A) |
≤ 25 dB(A) |
≤ 25 dB(A) |
Consumption: operating (standby) / night |
<5W / < 0.5 W |
<5W / < 0.5 W |
<5W / < 0.5 W |
Topology |
transformerless |
transformerless |
transformerless |
Cooling concept |
Natural cool |
Natural cool |
Natural cool |
Installation: Indoors / Outdoors(IP65 electronics /NEMA 4R ) |
yes /yes |
yes /yes |
yes /yes |
Features |
|
||
DC connection:MC3/MC4/H4 |
opt/opt/yes |
opt/opt/yes |
opt/opt/yes |
AC connection: Terminals |
yes |
yes |
yes |
LCD display |
yes |
yes |
yes |
Interfaces: Bluetooth / RS485/RS232 |
opt/opt/yes |
opt/opt/yes |
opt/opt/yes |
Warranty: 5 years / 10 years |
yes /opt |
yes /opt |
yes /opt |
Certificates and approvals |
Ul1741, UL1998, IEEE1547, CSA C22.2 No.107.1, FCC Part15(Class A&B) |